NeuroTrac™® MyoPlus2 

Options Quantity
NeuroTrac™ ® Myo PLUS2 - 2 Channel STIM, 2 Channel EMG
VM-PLUS2
  • The Classic Biofeedback / ETS / Stimulation device. A proper tool for training and progress assessment.
  • Pre-set programmes for Incontinence treatment, Sports and muscular development, neuro-muscular Rehabilitation.
  • Designed for Physiotherapist in mind to be used as a portable tool. Suitable as a personal trainer for in-clinic or home use (under guidance).
  • 2 channel EMG (Biofeedback) combined with 2 channels NMES (stimulation).
  • •2 channel ETS (EMG triggered stimulation) with stimulation on 2 channels.
  • •Simple single-phase or multiphase operation: multiphase allows EMG/ETS/STIM to be combined in one programme.
  • •Multilingual LCD screen and voice prompts for Biofeedback.
    • Manual and Automatic threshold control.
  • EMG Biofeedback between stimulation (muscle activity and tiredness indication when using muscle stimulation).
  • Stand-alone device or used in conjunction with established multilingual software.
  • •Up to 10 metres of wireless (Bluetooth) connection for NeuroTrac™ Software
  • •For home users: Produces and prints (with the optional PC Software) the comprehensive patient progress reports on a day to day basis providing average readings (2 channels) on work/rest, peak, onset and muscle release times, work and rest deviations and the average mA current.
  • •Used as a learning tool for both patient and clinician with emphasis on improving treatment techniques in the use of EMG and Neuromuscular stimulation

EMG (Biofeedback)
• Dual channel EMG
• EMG Range: 0.2 to 2000 ?V RMS (continuous)
• Sensitivity: 0.l ?V RMS
• Accuracy: 4% of ?V reading +/-0.3 ?V at 200 Hz
• Selectable Bandpass filter – 3db Bandwidth,
• a. Wide: 18 Hz +/- 4 Hz to 370 Hz +/- 10% – Reading below 235 microvolts 10 Hz +/-3 Hz to 370 Hz +/- 10% – Reading above 235 microvolts
• b. Narrow: 100 Hz +/- 5% to 370 Hz +/- 10%
• Notch filter: 50 Hz (Canada 60Hz) – 33 dbs (0. 1% accuracy)
• Common Mode Rejection Ratio: 130 dbs Minimum @ 50 Hz
• Work / Rest periods: 2-99 seconds
• Number of Trials: 1-99
STIM (Neuromuscular Stimulation)
• Dual channel Stimulator
• Amplitude: 0-90 mA into 500 Ohm load – actual mA will tend to be less than indicated due to Electrode impedance: at 1000 Ohms load (Electrodes in poor condition) the maximum will be limited to 75 mA, at 1500 Ohms load the maximum will be limited to 50 mA.
• Type: Constant current, maximum output voltage 70 Volts +5 / -10 Volts
• Waveform: Symmetrical, rectangular, bi-phasic with net zero DC current
• Pulse width selection: 50-450 ?S (2% accuracy)
• Pulse rate selection: 2-100 Hz (2% accuracy)
• Work / Rest periods: 2-99 seconds
• Time 1 – 99 minutes
• Ramp up time: 0.1 – 9.9 seconds
• Preset and user programmable treatment Programs
• Automatic output shut off with detection of open electrode above 0.5 mA

Battery: 4 x AA. Low battery indication at 5.4 volts +/- 0.2 volts, automatic shut off when voltage dropps below the low indication. Replace the batteries immediately! The device goes off automatically when not in use (energy saving): for example when in settings and no key pressed over 1 minute, when in stimulation mode (home screen) and all channels are 0mA.

Expected average battery set life [of standard 800 mAh, alkaline]:
a. MyoPlus2: 12-16 hours in STIM, 25 hours in EMG mode.
b. MyoPlus4: 8-16 hours in STIM, 25 hours in EMG mode.

Environmental Conditions for use:
+5 to +40 degrees Centigrade. 15-93% Humidity.

Environmental conditions for storage & transport:
-25 to +70 degrees Centigrade. 15-93% Humidity.

Physical Dimensions: Length 150 mm, Width 89 mm, Depth 35 mm

Weight: MyoPlus2 device: 0.16 Kg (without batteries).